 AC-DC
800 Watts SMR Series
* * * * * * *
xppower.com
Up to 900 W Peak Output Power Single Outputs from 12 V to 60 V Active PFC Remote On/Off Semi F47 Compliant Optional Current Share Optional Input & Output Connectors
Specification
Input
Input Voltage Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current Input Protection * * * * * * * 90-264 VAC (120-370 VDC) 47-63 Hz 12 A at 90 VAC, 6 A at 230 VAC 70 A at 230 VAC 0.99 typical <2.4 mA max at 264 VAC Fitted with a T12 A/250 V fuse
General
Efficiency Isolation * 80% min for 12 V model 82% min for others models at 230 VAC * 3000 VAC Input to Output 1500 VAC Input to Ground 250 VDC Output to Ground * 25 kHz PWM, 60 kHz PFC * 8.2 W/In3 * Green LED for Power On, Power Good TTL HIGH within 100-500 ms and LOW 1 ms before loss of regulation * 0.5 V to 3 V output denoting 0-100% output current * 150 kHrs min per MIL-HDBK-217F
Switching Frequency Power Density Signals
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Over/Undershoot Transient Response See tables 5% 1% 1% to meet ripple & noise spec 1.0 s at 230 VAC 40 ms typical 16 ms min at 120 VAC 0.5%, low line to high line 1%, 1-100% load (see note 4) 5% max 5% max deviation, 500 s recovery to within 1% for a 50% load change Ripple & Noise * 50 mV (Vo 5 V), 1% (Vo 12 V) (see note 2) Overvoltage Protection * 110-130% recycle input to reset Overtemperature * Measured internally with auto recovery Protection Overload Protection * 110-140% with auto recovery Short Circuit Protection * Trip and restart (Hiccup mode) Remote Sense * Compensates for up to 0.5 V line drop Remote On/Off * On = TTL Logic HIGH, or open circuit Off = TTL Logic LOW or short circuit Current Share * Optional single wire current share within 10% for up to 4 units (add suffix `-I' to model number) Note that this option includes output blocking diodes. Remote sense is not available with current share. * * * * * * * * * * * Current Monitor MTBF
Environmental
Operating Temperature * 0 to +70 C, derates from 100% load at +50 C to 50% load at +70 C Cooling * Internal fan Operating Humidity * 5-90%, non-condensing Storage Temperature * -20 C to +85 C Operating Altitude * 3000 m Vibration * 5-50 Hz, acceleration 7.35 ms2 on X, Y and Z axis
EMC & Safety
Emissions Harmonic Currents ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions * FCC Part 15 & EN55022 Level B conducted * EN61000-3-2-3-3 * EN61000-4-2, level 3 Perf Criteria A * EN61000-4-3, 3 V/m Perf Criteria A * EN61000-4-4, level 2 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, 3V Perf Criteria A * EN61000-4-11 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B * UL60950, CSA C22.2 No. 950, EN60950-1:2001, CE Mark LVD, SEMI F47 compliant (high line only) at 100% rated power output
Safety Approvals
AC-DC
Models and Ratings
Output Power 750 W Output Voltage(3,4) 12 V 15 V 18 V 24 V 27 V 36 V 48 V 54 V 60 V Output Current Maximum Peak(1) 62.50 A 75.00 A 50.00 A 56.00 A 41.67 A 50.00 A 33.39 A 37.50 A 29.62 A 33.33 A 25.00 A 29.60 A 16.67 A 18.75 A 14.81 A 16.67 A 13.33 A 15.00 A 120 150 180 240 270 360 480 540 600
SMR Series
Ripple & Noise(2) mV mV mV mV mV mV mV mV mV Model Number SMR800PS12 SMR800PS15 SMR800PS18 SMR800PS24 SMR800PS27 SMR800PS36 SMR800PS48 SMR800PS54 SMR800PS60
800 W
Notes
1. This peak can be taken for 500 s only, average power should not exceed the maximum power. 2. Ripple & Noise is measured using 0.1 F ceramic and 22 F electrolytic capacitor, 20 MHz bandwidth. 3. Alternative output voltages available. Consult sales. 4. Load regulation increases to 2% for 0-100% load change.
Mechanical Details
B Mounting Hole 8 Places A Mounting Hole 8 Places
0.22 (5.6) 0.25 (6.4)
0.07 (1.9) 0.02 (0.6)
0.22 (5.6) 0.25 (6.4) UNC6-32 (Zn-plated) A B B A
2.00 (50.8) 2.50 (63.5)
M4 (Zn (yellow) -plated)
2.09 (53.0)
5.00 (127.0)
1.59 (40.4)
CN3
Pin 7
Pin 1 2* 3 4 5 6* 7*
2.50 (63.5)
CN3 (Signals) Function Current monitor Current share Return Power good Remote On/Off -Remote sense +Remote sense
0.07 (1.9) 0.02 (0.6)
FAN
2.50 (63.5)
2.50 (63.5)
1.59 (40.3)
6.00 (152.4)
Pin 1
A B 1.75 (44.45) B 1.62 0.32 (8.25) (41.25) A 1.25 (31.9) 2.50 (63.6)
A B For SMS Version only
*If optional current share if fitted then remote sense function is excluded.
0.59 (15.0)
VOVO+
4.25 (108.0)
B A
LN
0.88 (22.25)
OPTION `-D' IEC320 or equivalent
STANDARD Terminal Block M3 Screw 3 Pins 8.25 mm center A B
9.17 (233.0)
Terminal Blocks M3.5 Screw 8 Pins 9.5 mm center
B
A 2.00 (50.8)
2.50 (63.5)
9.17 (233.0)
All dimensions are in inches (mm). Weight: 3.30 lbs (1.5 kg) approx. Logic connector CN3 mates with: JST XHP-7 or equivalent & JST SXH-002T-P0.6 crimp terminals. Maximum mounting screw penetration: 0.12 (3.0) on base & 0.25 (6.3) on each side.
Options
* Current share and internal oring diode add suffix `-I' to model number. Note that this option includes output blocking diodes. Remote sense is not available with current share. * Optional IEC320 inlet add suffix`-D' to model number. * Optional Molex output connector add suffix `-E' to model number. * For U-Channel version replace `SMR' in the model number with `SMS' e.g. SMS800PS12 (note that 25 CFM cooling air is required). Dimensions are 8.00(l) x 4.33(w) x 2.56(h) (203.2 x 110.0 x 65.0). * For top mounting fan version replace `SMR' in the model number with `SMT' e;g; SMT800PS12. Dimensions are 8.00(l) x 4.33(w) x 3.40(h) (203.2 x 110.0 x 86.4). * For multiple option codes place codes in alphabetical order. e.g. SMR800PS12-DI.
Application Notes
Parallel Connect with Current Share Option
Supply 1
Output Return CN3 Pin 2 Current Share V1
Remote On/Off
Power Good
+5 V
CN3 Pin 5, control connector ON/OFF
1K
PSU
LOAD
CN3 Pin 4, control connector Power Good
POWER GOOD
Comm
Supply 2
Output Return
CN3 Pin 3, control connector Return
CN3 Pin 3, control connector Return
POWER NOT GOOD
CN3 Pin 2 Current Share
Note: Applying <0.3 V or short between pins 5 and 3 turns the output OFF. Applying >4.5 V or open circuit between pins 5 and 3 turns output ON.
Sink current = 6 mA Source current = 4 mA
17-Apr-07


▲Up To Search▲   

 
Price & Availability of SMR800PS12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X